ci / bump (push) Successful in 24s
services/_runtime.py crashed the worker and reconciler on boot with `ModuleNotFoundError: No module named 'services._runtime'`, while every unit and integration gate was green and the API rolled out fine. The cause is packaging, not code. Each service Dockerfile copies only its own `services/<svc>/` subdir — `services/` itself is a namespace package with no __init__.py, so a file added at the `services/` root is never copied into any image. Tests import from the source tree, where the file exists, so nothing below the image boundary could catch it. The API survived only because it does not import the helper. Moved to svcforge_core.runtime, which `COPY libs/ libs/` packages into every image, next to adapters/tempyaml.py for the same reason. Added an import smoke test to the image job: `docker run --entrypoint python <image> -c "import services.<svc>.main"` loads the whole transitive graph inside the built image and fails the build before the digest is pushed. This is the one check the test suite structurally cannot perform — it runs against source, the image is a different filesystem — and it is exactly the gap this bug fell through.